The following parts are included in this
maintenance kit:
| 1 |
8100 Fuser |
RG5-4315 |
| 8 |
Feed/Separation Rollers |
RF5-1834 |
| 1 |
Transfer Roller |
RF9-1394 |
| 2 |
Gloves |
|
Damage to the core can occur if it is
packaged incorrectly. Re use this packaging to ship the core back.A core charge will be
applied if the core is received in non-repairable condition.
WA R N I N G
Turn the printer
off, unplug it, and allow it to sit for 30 minutes beforeperforming these maintenance procedures.
Fuser
Installation
-
Open the left side door. If duplex unit
is installed, remove it by pushing down on the green release
lever and pulling it towards you and out of the printer.
-
Locate the fuser's left and right blue locking levers. Turn each one downwards
90 degrees to unlock the fuser.
-
Grab
the handles on the far left and right side of the fuser. Lift it slightly and
pull it towards you until it is out of the printer.
-
With
the blue locking levers facing downward, slide the new fuser into the printer
and drop it into place.
-
Turn
the blue locking levers upward 90 degrees until they snap into place.
-
Reinstall the duplex unit if it was removed in step 1.
Feed/Separation
Roller Removal & Replacement
-
Pull
tray 2 open until it stops.
-
Lift
the blue lever on the right side of the tray and pull the tray from the
printer. Do the same with tray 3.
-
Locate the four feed/separation rollers
with the blue hub inside the printer (two for tray 2, and
two for tray 3). Pinch the tabs together and pull the rollers off of the
shafts.
-
Remove the four new feed/separation
rollers (PN: RF5-1834) from the bag. Install the new rollers
by sliding them onto each shaft until they snap into place. It may be
necessary to turn them while doing this.
-
Reinstall trays 2 and 3 in reverse fashion.
Transfer
Roller Replacement
Use The Latex Gloves When Replacing The
Transfer Roller Assembly
-
Open
the top cover and remove the toner cartridge.
-
Locate the blue gear on the far left
side of the transfer roller assembly. Gently lift up on this
gear until it is free from the retainer clip.
-
Slide the transfer roller assembly to the left and remove it from the printer.
-
Remove the old transfer roller from the transfer roller assembly and snap the
new one into place.
-
Install the right side shaft of the new transfer roller assembly into the
printer, then snap the left side down into the retainer clip.
-
Press down on both sides of the silver and black transfer roller guide until it
snaps into place.
-
Replace the toner cartridge, close the top cover and plug the printer in.
Clearing
The "PERFORM USER MAINTENANCE" Message (If Displayed)
-
Turn
the printer on and wait until "PERFORM USER MAINTENANCE" is
displayed.
-
Press the GO button so that its green indicator goes off and
"OFFLINE" is displayed.
-
Press the MENU button until "CONFIGURATION MENU" is displayed.
-
Press the ITEM button once, so that "SERVICE MESSAGE=ON" or
"SERVICE MESSAGE=OFF" is displayed.
-
If
"SERVICE MESSAGE=OFF"', press the SELECT button so that "*"
appears.
-
If
"SERVICE MESSAGE=ON", press the + button to change ON to OFF, then
press the SELECT button so that "*" appears.
|