Damage to the core can occur if it is
packaged incorrectly. Re use this packaging to ship the core
back. A core charge will be
applied if the core is received in non-repairable condition.
WA R N I N G
Turn the printer off, unplug it, and
allow it to sit for 30 minutes before performing these maintenance procedures.
Separation Pad & Paper Feed Roller Removal/Replacement
- Open the MF tray and lift the tab
to release and open the paper path door. Remove the toner
cartridge.
- Remove the separation pad by
pulling forward on its clear mylar tab.
- Push down on the tab behind the
center gear off the paper feed roller so that the shaft
lifts up. Gently pull the right side rubber roller forward
from its clip then pull the left side roller from its clip.
- Push down on the tab behind the
center gear. Snap the left side shaft of the new paper feed
roller into place, then the right side. The right side will
not be held in place as lightly as the left side, this is
normal.
- Drop the new separation pad into
place (with clear mylar tab on top). Press in on the center
until it snaps into place.
Very Important
Ensure that the lever to the left of the right side rubber roller is mounted UNDERNEATH
the shaft.
Fuser Removal
- Lift the spring loaded internal
access door.
- Locate and remove the five
collateral screws securing the fuser.
- Lift the left side of the fuser while
gently but firmly bending the left side of the paper path
door outward. After the shaft is clear of the holding tab, left the right side of
the fuser in the same manner. Pull the fuser form the inside of the paper path
door.
Transfer Roller Assembly Removal
- Lift up on the blue gear on the
left side of the transfer roller assembly until it snaps
free of its clip.
- Pull
the transfer roller assy forward and to the left and remove it from the inside
of the paper path door.
Pick Up
Roller Assembly Removal/Replacement
- Locate and remove the three black
screws securing the pick up roller assembly (one on the far
left side of the shaft, two on the far right side of the
shaft).
- Liftthe pick up roller assy and
remove it from the inside of the paper path door.
- Place the new pick up roller assembly
into position (with the solenoid and gear towards the
right), line up the left and right mounting brackets and resecure the three
screws (one on the left, two on the right).
Transfer Roller Assembly Replacement
Use The Latex Gloves When Replacing The Transfer Roller
- Pull the blue gear from the
transfer roller shaft.
- Grasp the mounting bracket and
gently, but firmly pull the transfer roller from the frame.
Keep your hand over the top of the shaft to contain the
shaft clip in case it pops off. Remove the transfer roller
from the frame.
- Snap the new transfer roller into
place. The long end goes towards the resistor and mounting
bracket. Use tweezers or a small flathead screwdriver to
replace the shaft clip, if necessary.
- Replace the blue gear onto the
shaft with its flat edge facing outwards.
- Slide the right side shaft end of
the transfer roller assembly into the clip.
- Mount the left side transfer roller
bracket on the pick up roller assembly shaft.
- Press down on the blue gear until it snaps into place.
Internal Access Door Assembly Removal/Replacement
- Lift the spring loaded internal
access door. Locate and remove the three self tapping
mounting screws (one black screw on the far left, two silver
screws on the far right).
- Lift the internal access from the
inside of the paper path door.
- Inspect the four oval rollers on
the paper path door. Clean them of any debris, dust or paper
and wipe them down with alcohol and a lint free towel.
- Open the spring loaded arms of the
new internal access door and position it on the inside of
the paper path door (the shorter arm with the three gears
goes toward the right).
Fuser Replacement
- Line up the five screw holes on the
new fuser and the inside of the paper path door.
- Pull the left side of the paper
path door outward gently, yet firmly and push down on the
left side of the fuser until it snaps into place. Install
the right side of the fuser in the same manner.
- Resecure the five collared screws.
- Close the spring loaded internal
access door.
|